2016年2月24日星期三

Diesel generator set will be shipped to Spain

Diesel generator set will be shipped to Spain,Spanish customers choose weichai diesel genset, silent canopy and trailer configuration.


2016年2月21日星期日

Battery maintainance on china diesel generator

Battery is  the important components for starting on china diesel generator, and generator supplier</ins> said its role is implementation with electric start and unit fuel system of diesel engine control and automatic control unit. 
Diesel generator battery maintenance tips: (1) with a damp cloth to external battery scrub. The panel, pile head (i.e., positive and negative two pole head) of dust, oil, white powder. This often scrubbing battery, battery will not pile head white powder accumulation of acid corrosion, its life will be longer. (2) open the battery cover , to check whether the water level in the normal position. In general, the battery side will have on the lower limit of the line for the user's reference. Such as the discovery of water level is lower than the marking, it is necessary to add distilled water, if there is no distilled water, filtered tap water can be used to emergency. The water can not be added too much, the standard is added to the upper and lower middle line. (3) check whether the normal battery charging. If the user has 3 meters, after starting the engine, look at the amount of the polarity of the battery voltage must more than 13V to be considered normal. Found that the charging voltage is too low, you need to ask professionals to overhaul the charging system. If there is no 3 meters, available visual method: after starting the engine, open the battery cover with water, look at each grid inside there is no bubble. Normal condition is continuous air bubbles out of the water, and the more fuel will take the more; if it is found that there is no bubble, it is very likely to is charging system has a problem. Special attention is to do the inspection will have to produce hydrogen, so test do not fire, in order to avoid the explosion and fire.

2016年2月19日星期五

diesel genset shipped to Kuwait

Diesel generator set shipped to Qingdao port, will arrive in Kuwait.
Through the communication with the customer, the customer is a very sensible man.
Because the problem of the lunar New Year holiday, we can't delivery.
Hope that the seller and the buyer understanding each other,So that we can be done more perfect cooperation.
If you want to buy diesel genset or you have any questions about diesel genset,you can contact us,we are glad to help you solve the problem.

2016年2月18日星期四

ATS diesel genset made in Huaquan power

ATS diesel generator experienced three stages of relay control, PLC (Programmable Logic Controller) control and intelligent controller , intelligent controller gradually from the end of the last century, beginning by the microcomputer and electronic components consisting of the very complex peripheral circuitry integrated into a module, which greatly simplifies the control line, also will be enhanced reliability.
ATS diesel generator controller consists of three main parts as below::

    1. The motor control section, including voltage regulation device, overload, short circuit protection unit and voltage regulator and so on.
    2. The diesel engine control section, mainly by the startup, shutdown operation, the electronic regulator and the liquid crystal display part of the module, etc., to achieve the operating state of the diesel engine to be monitored.

    3. The microcomputer control section, which is automatically controlled diesel generator core, mainly controlled by the host unit, consisting of a signal detection unit, the power drive unit, a display unit and a power supply unit parameters and the like.



2016年1月31日星期日

Battery maintainance on diesel generator

Battery is  the important components for starting on diesel genset,and generator supplier</ins> said its role is implementation with electric start and unit fuel system of diesel engine control and automatic control unit. 
Diesel generator battery maintenance tips: (1) with a damp cloth to external battery scrub. The panel, pile head (i.e., positive and negative two pole head) of dust, oil, white powder. This often scrubbing battery, battery will not pile head white powder accumulation of acid corrosion, its life will be longer. (2) open the battery cover , to check whether the water level in the normal position. In general, the battery side will have on the lower limit of the line for the user's reference. Such as the discovery of water level is lower than the marking, it is necessary to add distilled water, if there is no distilled water, filtered tap water can be used to emergency. The water can not be added too much, the standard is added to the upper and lower middle line. (3) check whether the normal battery charging. If the user has 3 meters, after starting the engine, look at the amount of the polarity of the battery voltage must more than 13V to be considered normal. Found that the charging voltage is too low, you need to ask professionals to overhaul the charging system. If there is no 3 meters, available visual method: after starting the engine, open the battery cover with water, look at each grid inside there is no bubble. Normal condition is continuous air bubbles out of the water, and the more fuel will take the more; if it is found that there is no bubble, it is very likely to is charging system has a problem. Special attention is to do the inspection will have to produce hydrogen, so test do not fire, in order to avoid the explosion and fire.
More questions about china diesel generator or other information, welcome to visit http://www.china-quan.com

2016年1月29日星期五

Features of Isuzu diesel generator set:

1.Full-load, minimum fuel consumption rate 198g/kW.h
2.Isuzu diesel generator are durable, reliable and enjoy easy maintenance, long life,
3.Dry cylinder liner are adopted, effectively avoid leakage of the engine and providing
convenient maintenance.
4.Isuzu diesel generator are eco-friendly products with low emission and noise.
Noise level of Steyr diesel engine applied in power station is merely 95 dB.
All models of this series have reached Euro II emission standards.

2016年1月28日星期四